Trendnet MultiTemp III 18-1106-33 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Trendnet MultiTemp III 18-1106-33. TRENDnet MultiTemp III 18-1106-33 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User Manual

MultiTemp®IIIUser Manual18-1106-33Edition ADAP H A R M A C I A B I O T E C H

Strany 2 - Important user information

3. Installationliquid pour into a large vessel using hydrostatic pressure. Thebath contains 3 litres of liquid, plus the volume in tubing andconnected

Strany 3 - Contents

4. Operation4. OperationFig. 2. Front panel of MultiTemp III.1. Mode selector 6. Mains switch2. Set value down 7. Control lamp cooling on/off3. Set va

Strany 4

4. Operationthe external system and the level in the bath will fall. Addmore liquid until the level is once again 2 cm below the topplate. If the safe

Strany 5 - 2. Safety information

4. Operation2. Use or to set the maximum allowed set tempe-rature. The factory pre-set value is 90.0 °C. 3. Confirm with bef

Strany 6 - 2.2 Safety

4. Operation5. Confirm with before the display returns to the actualtemperature value.Note: The new value is not saved until has been pres-sed.12

Strany 7

5. Trouble shooting5. Trouble shootingMessage on display Cause RemedyThe bath temperature has exceeded Pour in more liquid.the safety temperature lim

Strany 8 - 3. Installation

6. Maintenance6. MaintenanceWarning! Always disconnect MultiTemp III from the mains(Pull out the mains plug) before maintenance and/or service.Service

Strany 9

6. MaintenanceThe circuit breaker (thermal fuses) for MultiTemp III are loca-ted on the rear of the unit.Note: If the circuit breaker has been trigger

Strany 10 - 3.5 Mains

7. Detailed Description7. Detailed DescriptionMultiTemp III regulates temperature by balancing the effectsof constant cooling and controlled pulses of

Strany 11 - 4. Operation

7. Detailed DescriptionMains Switch. Starts the cooling compressor and the pumpmotor that circulates the temperature controlled liquid.Activates the h

Strany 12

Reading this entire manualis necessary for full under-standing and safe use of this product.Should you have any comments onthis manual, we will be ple

Strany 13

7. Detailed DescriptionGeneral cut-offThe heater, the compressor and the circulation pump can beswitched off by a relay built into the unit. This gene

Strany 14

7. Detailed DescriptionAccurate Setting of Temperature LimitIf a more accurate temperature limit is required, for example50 °C, follow the procedure b

Strany 15 - 5. Trouble shooting

7. Detailed DescriptionNote: Although this feature activates the general cut-off, it isnot a dedicated ”safety-function” of the type listedabove. When

Strany 16 - 6. Maintenance

7. Detailed DescriptionTo start MultiTemp III in 8 mode ON, follow the instructionsbelow:1. Check that all tubings are firmly connected and securedwi

Strany 17 - 6.2 Fuses

8. Technical specifiations8. TechnicalspecificationsTechnical specifications (ambient temperature 20 °C)Working temperature range -10 to 90 °CTemperat

Strany 18 - 7. Detailed Description

9. Ordering informationDesignation Code No.MultiTemp III 100-120 V 18-1102-77MultiTemp III 220-240 V 18-1102-78AccessoriesItem Quantity Code No.Coolin

Strany 20 - 7.4 Description

Short instructionsNote: The following short instructions are intended as a guide to users who are fully familiar with safety procedures and operating

Strany 21 - Sensor check

Contents1. Introduction... 32. Safety information ...

Strany 23 - Resetting mode 8 to OFF

1. Introduction and 2. Safety information1. IntroductionMultiTemp®III circulates constant temperature liquid toexternal electrophoresis equipment. Th

Strany 24 - 8. Technical

1. Introduction and 2. Safety information7. Do not use the circulator beyond its specifications or forother than its intended use. 8. Do not touch th

Strany 25 - 9. Ordering information

1. Introduction and 2. Safety informationGeneral cut-offThe heater, the compressor and the circulation pump can beswitched off by a relay built into

Strany 26

3. Installation3. Installation1. Check the contents against the packing list supplied. Inspectfor any damage that may have occurred during transit. Re

Strany 27 - Short instructions

3. InstallationSilicone tubing (inner diameter 8 mm) can be used over theentire working temperature range of the unit. PVC tubingcan only be used in t